Steca PA 15

Remote control, accessories for Steca Power Tarom

Description

The Steca Power Tarom charge controllers send out signals (125 kHz at 300 baud) that are modulated on the DC line and received by the Steca PA 15 remote control.
These signals contain information about the state of charge (SOC) of the battery. The Steca PA 15 has five different operating modes (see below), which can be set using five different jumper positions. The maximum switching capacity of 15 A can be optionally expanded to up to 200 A with a Steca PA EV200 DC relay.

Features

Product features

  • Receives information on SOC and time (day/night)
  • Load control via priority assignment
  • Adjustable SOC thresholds
  • Connects a maximum of 9 solar arrays in parallel
  • Current surge switch function

Electronic protection functions

  • Switches off load if there is no signal
  • Reverse polarity protection by internal fuse
  • Overtemperature and overload protection

Operation

  • Configuration by jumpers

Modes of operation

  • Management of parallel solar generators
  • When the battery is full, excess energy is redirected to additional loads such as pumps, water heaters
  • Automatic start / stop of diesel or wind back-up generators
  • Night light function
  • Acoustic alarm at deep discharge or overheating

Certificates

  • Compliant with European Standards (CE)
  • Made in Germany
  • Developed in Germany
  • Manufactured according to ISO 9001 and ISO 14001

Downloads

  •  Steca PA 15 certificate CE - PA 15 · pdf · 0.745 MB
  •  Steca PA 15 Datenblatt DE · pdf · 0,928 MB
  •  Steca PA 15 Datenblatt EN · pdf · 0.928 MB
  •  Steca PA 15 manual DE · pdf · 1.878 MB
  •  Steca PA 15 manual EN · pdf · 1.878 MB
  •  Steca PA 15 manual ES · pdf · 1.739 MB
  •  Steca PA 15 product pic 3D · jpg, 300 DPI, high quality · 2.557 MB
  •  Steca PA 15 product pic 3D · jpg, 72 DPI, web quality · 0.695 MB
  •  Steca PA 15 product pic · jpg, 300 DPI, high quality · 2.692 MB
  •  Steca PA 15 product pic · jpg, 72 DPI, web quality · 0.695 MB

Technical data

 PA 15
Characterisation of the operating performance
Power supply
10.5 V … 60 V DC, 5 mA
Data transmission
300 Baud
Transmission frequency
125 kHz signal frequency, 450 kHz intermediate freqency
DC output side
Load current
15 A, 10 A at 40 °C, 100 A pulse < 10 μs
Safety
Overload protection
by 15 A fuse
Wrong polarity protection
fuse
Operating conditions
Ambient temperature
-10 °C … +50 °C
Fitting and construction
Terminal (fine / single wire)
2.5 mm² / 4 mm² - AWG 14 / 12
Degree of protection
IP 22
Dimensions (X x Y x Z)
98 x 87 x 34 mm
Weight
110 g
 
  • Inverters must not be connected to the load output.